Data Center > Design/Build 과정
[영어 Live] CNCDP (Certified Network Cabling Design Professional)
- 강의기간
-
교육 시작일 후 2일
- 난이도
- 중급
- 수강일
- 2일, 09:00~18:00
- 수강료
-
1,500,000원
KRW (KR)
- 환급
-
비환급과정
※ 비환급과정(면세) 입니다.
- 과목코드
- ABC232
※ 본 과정을 신청하는 경우 한국 교육서비스의 Terms&Conditions 에 동의하는 것으로 간주합니다. |
과정소개 |
한국휴렛팩커드 교육센터는 2024 EPI Silver Partner입니다. After completion of the course the participant will be able to: - Understand the various standards for network cabling systems, the models and how to apply these to the network design.
- Design the user cabling and patching system for commercial buildings.
- Design the network cabling and patching system for data centres.
- Design the backbones for both indoor and outdoor cabling.
- Select the proper cabling containment/ pathways for network installations.
- Apply the correct installation practices and avoid common mistakes.
- Define the right testing criteria and methods for copper and fiber systems
|
수강대상 |
The primary audience for this course is any IT, facilities or data centre professional, consultant and/or those who work in network cabling system design, implementation and operation.
|
교육내용 |
Introduction to Structured Cabling System (SCS) - Brief history of SCS
- Basic copper and fibre transmission
- Copper and fibre cabling
- Single and multimode fibre
- Step/graded index multimode fibre
- Difference between Commercial Wiring and data centre cabling
- Development of standards
- Role of standards
- ANSI/TIA 568 standard
- Common standards
- The new usage of cabling to support Smart building
Horizontal and Administration - Commercial Building - Standard diagram recap: ANSI/TIA-568
- Functional elements and example
- Scenario A: Determine the number of work areas
- Scenario B: Determine the number of user locations
- Zone wiring
- Administration: Interconnect and cross-connect
- Angled and flat panels
- Creating a cabling schematic design
- Convert schematic into physical layout
- Calculating the material list
Horizontal and Administration - Data Centre - Standard diagram recap: TIA-942
- Basic/Reduced/Typical data centre setup
- Traditional 3 layers network design/ Spine and Leaf network design
- Select termination hardware
- Administration design
- ToR/EoR/Spine & Leaf cabling design
- Network and cabling resiliency
- Create cabling schematic design for ToR/EoR
- Convert into patch panel/rack layout
- Calculate the material list for ToR/EoR
Building Backbone - Commercial Building - Backbone diagram
- Calculate the copper backbone requirements per Telecom Room (TR)
- Calculate the fibre backbone requirements per Telecom Room
- Summarize the building backbone requirements
- Recognised cables
- Backbone Patch panels
- The maximum backbone distances
- Create cabling schematic design
- Converting the schematic design into patch panel/ rack layout
Building Backbone - Data Centre - TIA-942 based backbone topology
- TIA-942 backbone requirements
- Recognised backbone cable
- ToR/EoR/Spine and Leaf
- Backbone distance estimation
- Resiliency of backbone cable routes
- Creating cabling schematic design
- Converting the schematic design into patch panel/ rack layout
- Field and Fusion Termination for fibre connectors
- Pre-terminated fibre trunk and copper cables
Architectural Considerations - ANSI/TIA569-D Cable pathway and spaces
- Common requirements for the rooms
- Definition of the rooms
- Entrance Room/Demarcation
- Ceiling and floor pathways types
- Cable trays/basket/ladder/conduit
- Inner duct/sleeve/slot
- Calculating of pathway size
- Cable run best practices
- Cable management/AIM
- Grounding and bonding
- Separation distance requirements for copper cabling to power cabling
- Fire stopping
- Fire rated barrier
- Fire rated jacket cable
Campus / Outdoor Backbone - Common campus cable installation and cable types : Aerial cable / Direct-buried / Underground in-conduit
- Outdoor cable installation planning
- Lightning / surge protection
- Approved ground for surge protector
- Creating a schematic diagram
- Converting a schematic into a physical layout
Site Inspection and Testing - Visual site inspection notes
- Installation common issues
- Copper testing standard
- Permanent link / Channel / Patch cord / MPTL testing configuration
- Fibre connectors
- Fibre testing standard
- Tier 1 & 2 certification
- Fibre link definition
- Fibre testing steps
- Fibre inspection and cleaning
- Calibrating the test sets - 3 methods
- Setting up mandrel for testing
- Fibre loss budget calculation
- G.657 Bend insensitive fibre
- Optical Time-Domain Reflectometer (OTDR)
|
선수과목 |
There is no specific prerequisite for the CNCDP® course. However, participants who already have at least one or two years’ experience in a IT, data centre or facilities environment may be best suited. Those with no experience just yet are most welcome to participate.
|
다음과목 |
|
- 교육장
- 실시간온라인교육
- 강의장
- MyRoom
- 주소
- 본 과정은 실시간 온라인으로 진행되는 과정으로 개강확정 후 접속 URL을 별도 안내드립니다.
- 전화
- 1661-9080
- 팩스
- 주차
-
불가능
- 안내
-
코로나 19 감염 예방을 위해 집합교육 참석이 어려운 분들을 위한 실시간 온라인 교육입니다.