[영어 Live] CNCDP (Certified Network Cabling Design Professional)
강의기간
교육 시작일 후 2일
난이도
중급
수강일
2일, 09:00~18:00
수강료
1,500,000원 KRW (KR)
환급
비환급과정
※ 비환급과정(면세) 입니다.
과목코드
ABC232
과정개요 교육장 안내
※ 본 과정을 신청하는 경우 한국 교육서비스의 Terms&Conditions 에 동의하는 것으로 간주합니다.
과정소개

EPI한국휴렛팩커드 교육센터는 2024 EPI Silver Partner입니다.

 

After completion of the course the participant will be able to:

  • Understand the various standards for network cabling systems, the models and how to apply these to the network design.
  • Design the user cabling and patching system for commercial buildings.
  • Design the network cabling and patching system for data centres.
  • Design the backbones for both indoor and outdoor cabling.
  • Select the proper cabling containment/ pathways for network installations.
  • Apply the correct installation practices and avoid common mistakes.
  • Define the right testing criteria and methods for copper and fiber systems
수강대상

The primary audience for this course is any IT, facilities or data centre professional, consultant and/or those who work in network cabling system design, implementation and operation.

교육내용

Introduction to Structured Cabling System (SCS) 

  • Brief history of SCS
  • Basic copper and fibre transmission
  • Copper and fibre cabling
  • Single and multimode fibre
  • Step/graded index multimode fibre
  • Difference between Commercial Wiring and data centre cabling
  • Development of standards
  • Role of standards
  • ANSI/TIA 568 standard
  • Common standards
  • The new usage of cabling to support Smart building

Horizontal and Administration - Commercial Building

  • Standard diagram recap: ANSI/TIA-568
  • Functional elements and example
  • Scenario A: Determine the number of work areas
  • Scenario B: Determine the number of user locations
  • Zone wiring
  • Administration: Interconnect and cross-connect
  • Angled and flat panels
  • Creating a cabling schematic design
  • Convert schematic into physical layout
  • Calculating the material list

Horizontal and Administration - Data Centre

  • Standard diagram recap: TIA-942
  • Basic/Reduced/Typical data centre setup
  • Traditional 3 layers network design/ Spine and Leaf network design
  • Select termination hardware
  • Administration design
  • ToR/EoR/Spine & Leaf cabling design
  • Network and cabling resiliency
  • Create cabling schematic design for ToR/EoR
  • Convert into patch panel/rack layout
  • Calculate the material list for ToR/EoR

Building Backbone - Commercial Building 

  • Backbone diagram
  • Calculate the copper backbone requirements per Telecom Room (TR)
  • Calculate the fibre backbone requirements per Telecom Room
  • Summarize the building backbone requirements
  • Recognised cables
  • Backbone Patch panels
  • The maximum backbone distances
  • Create cabling schematic design
  • Converting the schematic design into patch panel/ rack layout

Building Backbone - Data Centre

  • TIA-942 based backbone topology
  • TIA-942 backbone requirements
  • Recognised backbone cable
  • ToR/EoR/Spine and Leaf
  • Backbone distance estimation
  • Resiliency of backbone cable routes
  • Creating cabling schematic design
  • Converting the schematic design into patch panel/ rack layout
  • Field and Fusion Termination for fibre connectors
  • Pre-terminated fibre trunk and copper cables 

Architectural Considerations

  • ANSI/TIA569-D Cable pathway and spaces
  • Common requirements for the rooms
  • Definition of the rooms
  • Entrance Room/Demarcation
  • Ceiling and floor pathways types
  • Cable trays/basket/ladder/conduit
  • Inner duct/sleeve/slot
  • Calculating of pathway size
  • Cable run best practices
  • Cable management/AIM
  • Grounding and bonding
  • Separation distance requirements for copper cabling to power cabling
  • Fire stopping
  • Fire rated barrier
  • Fire rated jacket cable

Campus / Outdoor Backbone

  • Common campus cable installation and cable types : Aerial cable / Direct-buried / Underground in-conduit
  • Outdoor cable installation planning
  • Lightning / surge protection
  • Approved ground for surge protector
  • Creating a schematic diagram
  • Converting a schematic into a physical layout

Site Inspection and Testing

  • Visual site inspection notes
  • Installation common issues
  • Copper testing standard
  • Permanent link / Channel / Patch cord / MPTL testing configuration
  • Fibre connectors
  • Fibre testing standard
  • Tier 1 & 2 certification
  • Fibre link definition
  • Fibre testing steps
  • Fibre inspection and cleaning
  • Calibrating the test sets - 3 methods
  • Setting up mandrel for testing
  • Fibre loss budget calculation
  • G.657 Bend insensitive fibre
  • Optical Time-Domain Reflectometer (OTDR)